Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiation Oncology ; (6): 1088-1091, 2016.
Article in Chinese | WPRIM | ID: wpr-503787

ABSTRACT

Objective To evaluate the feasibility of keeping the consistency of bladder filing by a Bladderscan ( BS ) device during radiotherapy for rectal cancer. Methods The bladder volume was measured using a BS device and recorded. To verify the reliability of the BS measurement, the urinary output was determined by a measuring glass after complete urinary discharge. The bladder volume of 42 patients determined by the planning computed tomography ( CT) scans was used as the standard urinary volume. The bladder volume was measured using the BS device before radiotherapy every day. The chief complaint urinary volume was determined as the bladder volume when a patient felt a strong urge to urinate. The controlled urinary volume was determined as the urinary output intervened by the BS device to reach the standard urinary volume. Comparison was made by t test and data was assessed by Pearson correlation analysis. Results There was no significant difference in obtained urinary volume between the BS device and the planning CT scan ( P=0?84) . The urinary volume measured by the measuring glass was correlated with that measured by the BS device ( P=0?00 ) . The ability to hold urine in all patients was gradually weakened during treatment. The controlled urinary volume had a significantly smaller decrease after 1, 2, 3, 4, and 5 weeks of treatment than the chief complaint urinary volume ( 5% vs. 21%;6% vs. 20%;6% vs. 20%, 4% vs. 21%;11% vs. 26%;all P=0?00) . Conclusions Patients have a gradually decreased urinary volume during treatment. The intervention by the BS device gives a bladder volume close to that in the planning system, which results in a consistent bladder filling.

2.
Chinese Journal of Radiation Oncology ; (6): 322-325, 2011.
Article in Chinese | WPRIM | ID: wpr-416603

ABSTRACT

Objective To investigate the positioning errors of head and neck during intensity-modulated radiation therapy of nasopharyngeal carcinoma.Methods Nineteen patients with middle-advanced nasopharyngeal carcinoma (T2-4N1-3M0), treated by intensity-modulated radiation therapy, underwent repeated CT during their 6-week treatment course.All the patients were immobilized by head-neck-shoulder thermoplastic mask.We evaluated their anatomic landmark coordinated in a total of 66 repeated CT data sets and respective x, y, z shifts relative to their position in the planning CT.ResultsThe positioning error of the neck was 2.44 mm±2.24 mm,2.05 mm±1.42 mm,1.83 mm±1.53 mm in x, y, z respectively.And that of the head was 1.05 mm±0.87 mm,1.23 mm±1.05 mm,1.17 mm±1.55 mm respectively.The positioning error between neck and head have respectively statistical difference (t=-6.58,-5.28,-3.42,P=0.000,0.000,0.001).The system error of the neck was 2.33,1.67 and 1.56 higher than that of the head, respectively in left-right, vertical and head-foot directions;and the random error of neck was 2.57,1.34 and 0.99 higher than that of head respectively.Conclusions In the process of the intensity-modulated radiation therapy of nasopharyngeal carcinoma, with the immobilization by head-neck-shoulder thermoplastic mask, the positioning error of neck is higher than that of head.

SELECTION OF CITATIONS
SEARCH DETAIL